A Mathematical Model and Calibration Procedure for Galvanometric Laser Scanning Systems
View/ Open
Date
2011Author
Manakov, Alkhazur
Seidel, Hans-Peter
Ihrke, Ivo
Metadata
Show full item recordAbstract
Laser galvanometric scanning systems are commonly used in various fields such as three dimensional scanning, medical imaging, material processing, measurement devices and laser display systems. The systems of such kind suffer from distortions. On top of that they do not have a center of projection, which makes it impossible to use common projector calibration procedures. The paper presents a novel mathematical model to predict the image distortions caused by galvanometric mirror scanning systems. In addition, we describe a calibration procedure for recovering its intrinsic and extrinsic parameters.
BibTeX
@inproceedings {10.2312:PE:VMV:VMV11:207-214,
booktitle = {Vision, Modeling, and Visualization (2011)},
editor = {Peter Eisert and Joachim Hornegger and Konrad Polthier},
title = {{A Mathematical Model and Calibration Procedure for Galvanometric Laser Scanning Systems}},
author = {Manakov, Alkhazur and Seidel, Hans-Peter and Ihrke, Ivo},
year = {2011},
publisher = {The Eurographics Association},
ISBN = {978-3-905673-85-2},
DOI = {10.2312/PE/VMV/VMV11/207-214}
}
booktitle = {Vision, Modeling, and Visualization (2011)},
editor = {Peter Eisert and Joachim Hornegger and Konrad Polthier},
title = {{A Mathematical Model and Calibration Procedure for Galvanometric Laser Scanning Systems}},
author = {Manakov, Alkhazur and Seidel, Hans-Peter and Ihrke, Ivo},
year = {2011},
publisher = {The Eurographics Association},
ISBN = {978-3-905673-85-2},
DOI = {10.2312/PE/VMV/VMV11/207-214}
}